skip to main content


Search for: All records

Creators/Authors contains: "Choi, Gihoon"

Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher. Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?

Some links on this page may take you to non-federal websites. Their policies may differ from this site.

  1. Abstract

    Mechanical properties have emerged as a significant label-free marker for characterizing deformable particles such as cells. Here, we demonstrated the first single-particle-resolved, cytometry-like deformability-activated sorting in the continuous flow on a microfluidic chip. Compared with existing deformability-based sorting techniques, the microfluidic device presented in this work measures the deformability and immediately sorts the particles one-by-one in real time. It integrates the transit-time-based deformability measurement and active hydrodynamic sorting onto a single chip. We identified the critical factors that affect the sorting dynamics by modeling and experimental approaches. We found that the device throughput is determined by the summation of the sensing, buffering, and sorting time. A total time of ~100 ms is used for analyzing and sorting a single particle, leading to a throughput of 600 particles/min. We synthesized poly(ethylene glycol) diacrylate (PEGDA) hydrogel beads as the deformability model for device validation and performance evaluation. A deformability-activated sorting purity of 88% and an average efficiency of 73% were achieved. We anticipate that the ability to actively measure and sort individual particles one-by-one in a continuous flow would find applications in cell-mechanotyping studies such as correlational studies of the cell mechanical phenotype and molecular mechanism.

     
    more » « less
  2. Most lab-on-a-disc platforms use centrifugal force to pump liquids. In this work, we demonstrated a novel energy efficient non-centrifugal lab-on-a-disc nucleic acid testing device in which no liquid motion is involved. Streamlined DNA extraction, amplification, and real-time detection on a single microfluidic reagent disc are achieved by actuating the DNA-carrying magnetic beads against stationary reagent droplets. Using malaria spiked whole blood as a testing model, we demonstrated an excellent detection limit of 0.5 parasites/µl, sufficient for detecting asymptomatic malaria parasite carriers. 
    more » « less